Datacenter site intelligence

Find your next datacenter site — and how fast you can power it.

GridCensus scores 147,272 candidate locations across the US on power availability, speed-to-power, fiber, water, and hazard. Screen states, counties, grid regions, and site types in seconds.

At a glance

GridCensus is a US datacenter site-selection dataset: 147,272 candidate sites scored 0–100 on power, speed-to-power, fiber, water and hazard (national average 53.2), alongside 2,442 operating datacenters, 1,388 internet-exchange facilities, 16,654 named electric substations and 2,085 retired power plants and brownfields. Georgia has the highest average readiness score (57.1).
◆ Loading atlas…

The readiness atlas

Explore every state by average DC Readiness, then zoom in to 147,272 scored candidate sites. Click any site for its full profile.

Open full-screen explorer →
Sites in view
0
Avg readiness
—
Syncing
DC Readiness
Prime≥ 75
Strong60–75
Fair40–60
Weak≤ 40
147,272
Scored candidate sites
53.2/100
Avg DC Readiness
5.8M MW
Catalogued candidate capacity
theoretical aggregate
4.2 yrs
Avg queue wait

Which states score highest for datacenter sites?

On average DC Readiness, the top five states are Georgia (57.1), South Carolina (57.1), Tennessee (57.0), Delaware (56.9), Connecticut (56.7), against a national average of 53.2. 29 of 51 states beat that average. Indiana has the most candidate sites (8,629), followed by California (8,490). The shortest average interconnection-queue wait is in Montana (1.1 yrs); the national average is 4.2 years and the longest is in California (7.6 yrs).

How are candidate sites split across grid regions and land types?

By grid operator, PJM holds 31,769 (22%), MISO holds 31,047 (21%), WECC holds 24,461 (17%), SERC holds 21,546 (15%), SPP holds 16,814 (11%), CAISO holds 7,921 (5%), ISO-NE holds 5,817 (4%), ERCOT holds 4,035 (3%), NYISO holds 2,860 (2%) of the 147,272 sites. By land type, Substation-Adjacent 38,820, Industrial 35,788, Former Mine 26,205, Greenfield 18,112, Federal Excess 17,528, Manufacturing 7,657, Shovel-Ready 2,365, Brownfield 771, Military BRAC 26. Substation-Adjacent sites have the highest average readiness score (57.5); federal excess sites the lowest (47.5).

What infrastructure data sits behind the scores?

Every candidate site is scored against the infrastructure around it. The catalog of 2,442 existing datacenters is most concentrated in Virginia (379), Texas (268), Oregon (168); Ashburn, Virginia alone has 66. The 1,388 internet-exchange and colocation facilities from PeeringDB have a median of 2 connected networks each. Of 75,328 HIFLD substation points, 16,654 carry a station name; the rest are unnamed points, line taps, risers and dead-ends. Retired power plants and EPA-listed brownfields (2,085) are listed separately as reuse candidates.

Browse the infrastructure records

Datacenter rankings

Top 20 highest-scored sites nationwide

Ranked by DC Readiness across all 147,272 candidate sites.

Top scored US datacenter sites
SiteTypeStateCountyVoltageCapacityQueue waitScore
COLSTRIPSubstation-AdjacentMTRosebud County500 kV1,000 MW1.1 yrs75.8
WIDOWS CREEK 500KVSubstation-AdjacentALDade County500 kV1,000 MW3.9 yrs73.0
PIN HOOKSubstation-AdjacentTNDavidson County500 kV1,000 MW3.9 yrs72.8
UAMPS Carbon Free Power PlantBrownfieldIDBonneville County46 kV762 MW5.0 yrs72.4
MYSTICSubstation-AdjacentMASuffolk County345 kV600 MW4.3 yrs72.4
K STREETSubstation-AdjacentMASuffolk County345 kV600 MW4.3 yrs72.4
OAK CREEK STATIONSubstation-AdjacentWIMilwaukee County345 kV600 MW4.3 yrs72.3
RAINEYSubstation-AdjacentNYNew York County345 kV600 MW4.3 yrs72.2
CANE RUNSubstation-AdjacentKYFloyd County345 kV600 MW3.9 yrs72.2
BULL RUNSubstation-AdjacentTNAnderson County500 kV1,000 MW3.9 yrs72.2
RACCOON MOUNTAINSubstation-AdjacentTNHamilton County500 kV1,000 MW3.9 yrs72.0
WILLOW GLEN (500KV)Substation-AdjacentLAAscension Parish500 kV1,000 MW4.3 yrs71.9
AUTAUGAVILLESubstation-AdjacentALAutauga County500 kV1,000 MW3.9 yrs71.9
JOHNSONVILLESubstation-AdjacentTNBenton County500 kV1,000 MW3.9 yrs71.8
FREEPORTSubstation-AdjacentTNDeSoto County500 kV1,000 MW3.9 yrs71.8
BRIDGEPORT RESCOSubstation-AdjacentCTGreater Bridgeport Planning Region345 kV600 MW4.3 yrs71.7
NEWPORT TIESubstation-AdjacentSCYork County500 kV1,000 MW3.9 yrs71.6
VOLUNTEERSubstation-AdjacentTNKnox County500 kV1,000 MW3.9 yrs71.5
MONTGOMERYSubstation-AdjacentTNMontgomery County500 kV1,000 MW3.9 yrs71.4
SHAWNEESubstation-AdjacentKYMassac County500 kV1,000 MW4.3 yrs71.4

How scoring works

DC Readiness is a 0–100 weighted blend of fourteen factors — power (20%), speed-to-power (20%, scored on market interconnection speed; Texas scores high, though ERCOT has paused energizing new datacenter loads of 75 MW or more since August 2026), fiber (12%), energy cost (10%), and smaller weights for water, hazard, buildability, labor, existing-datacenter ecosystem, land, construction cost, gas pipeline, tax, and climate. Scores are screening estimates from public data sources; catalogued capacity is a theoretical aggregate, not deliverable power. Read the full methodology →

Frequently asked questions

What is GridCensus?

GridCensus is a datacenter site-selection screening tool. It scores 147,272 candidate locations across the United States on power, speed-to-power, fiber, water, and hazard, using public infrastructure data.

How many datacenter sites are scored?

147,272 candidate sites across all 50 states and DC, spanning nine site types and nine ISO/RTO regions.

What is 'speed-to-power'?

Speed-to-power is how quickly a site can be energized — driven by proximity to existing transmission, substation adjacency, and interconnection-queue dynamics.

Are the scores official capacity figures?

No. Scores are screening estimates from public data, and catalogued candidate capacity is a theoretical aggregate of per-site estimates — not deliverable power. See the methodology page.

Which state scores highest for datacenter development?

Georgia has the highest average DC Readiness score (57.1 of 100) across its candidate sites, followed by South Carolina (57.1). The national average is 53.2.

How many existing datacenters does GridCensus track?

2,442 operating US datacenter facilities, one record per facility. Virginia has 379, Texas has 268, Oregon has 168 — the three largest state counts.

Where does the internet-exchange and substation data come from?

Internet-exchange and colocation facilities (1,388) come from PeeringDB; substations (16,654 with a station name) come from HIFLD electric substation and transmission-line data; retired power plants and brownfields (2,085) come from EIA-860 and EPA records.

Dataset updated . Screening estimates derived from public data sources.

Go deeper than the public screen

Every site and score is free to browse. Pro adds Watchtower on 25 sites, alerts when new candidate sites, datacenters or interconnection-queue requests appear in your markets, score and capacity history, and CSV export. Enterprise adds team seats, weekly data files for all 147,272 sites, the REST API and an MCP server for AI tools.