Skip to content
Gridcensus

TAP302762

Substation

California · PACIFIC GAS & ELECTRIC COMPANY

Max voltage
60
kV

At a glance

TAP302762 is a 60 kV electric substation in California on PACIFIC GAS & ELECTRIC COMPANY's transmission network, recorded in the HIFLD transmission dataset. 3 transmission lines connect to it. The highest-scoring datacenter candidate site within about 25 miles is OLINDA in Tehama County, with a DC Readiness score of 55/100.

TAP302762 is an electric transmission substation in California, on PACIFIC GAS & ELECTRIC COMPANY's transmission network. It is classified as distribution (<69 kv) and connects 3 transmission lines. Substation proximity is one of the strongest speed-to-power signals for siting a datacenter — interconnection distance to an energized, high-voltage bus is often the binding constraint on time-to-energization.

Voltage & classification

Max voltage60 kV
Min voltage60 kV
Voltage classDistribution (<69 kV)
Connected lines3

Ownership

Line owner (most lines)PACIFIC GAS & ELECTRIC COMPANY
Coordinates40.5786, -122.3529

Connected transmission lines

Lines terminating at or passing through this substation, by HIFLD line ID, highest voltage first.

Line IDVoltageOwnerStatusLength
#30428660 kVPACIFIC GAS & ELECTRIC COMPANYIN SERVICE3.4 mi
#30477360 kVPACIFIC GAS & ELECTRIC COMPANYIN SERVICE3.1 mi
#31208760 kVREDDING ELECTRIC UTILITYIN SERVICE1.9 mi

Browse the full transmission-line map →

Nearby datacenter candidate sites

Scored candidate sites within roughly 25 miles of TAP302762, ranked by DC Readiness. Sites this close to an energized substation carry a strong speed-to-power advantage.

Candidate sites near TAP302762 substation
SiteTypeStateCountyVoltageCapacityQueue waitScore
OLINDASubstation-AdjacentCATehama County500 kV1,000 MW7.6 yrs54.5
FLANNIGANSubstation-AdjacentCAShasta County230 kV300 MW7.6 yrs50.7
SHASTASubstation-AdjacentCAShasta County230 kV300 MW7.6 yrs50.7
KESWICKSubstation-AdjacentCAShasta County230 kV300 MW7.6 yrs50.6
CARRSubstation-AdjacentCATrinity County230 kV300 MW7.6 yrs50.6
SPRING CREEKSubstation-AdjacentCAShasta County230 kV300 MW7.6 yrs50.5
PIT 7Substation-AdjacentCAShasta County230 kV300 MW7.6 yrs50.5
COTTONWOODSubstation-AdjacentCATehama County230 kV300 MW7.6 yrs50.4

Who owns the transmission lines at TAP302762?

The 3 connected lines listed above are owned by PACIFIC GAS & ELECTRIC COMPANY, REDDING ELECTRIC UTILITY. Line voltages range from 60 kV to 60 kV. Their combined recorded length is about 8.4 miles.

How do candidate sites near TAP302762 score?

The 8 highest-scoring candidate sites within about 25 miles range from 50 to 55 on the 0–100 DC Readiness scale. They fall in Tehama County, Shasta County, Trinity County. The California average across 8,490 scored sites is 45.4. 1,573 of those California sites are classed as substation sites (candidate locations generated at an existing substation).

Frequently asked questions

What voltage is TAP302762 substation?

TAP302762 has a maximum voltage of 60 kV. That places it in the below 69 kV band. The median named US substation in this dataset is 115 kV, so TAP302762 is below the national midpoint.

How many transmission lines connect to TAP302762 substation?

3 transmission lines terminate at or pass through TAP302762 in the HIFLD line data. The connected lines listed here run at 60 kV. Together the listed lines cover about 8.4 miles.

Who owns TAP302762 substation?

HIFLD does not publish substation owners directly. Most of the transmission lines that end at TAP302762 belong to PACIFIC GAS & ELECTRIC COMPANY, and others to REDDING ELECTRIC UTILITY. GridCensus derives this from the line data, so confirm ownership with the utility for anything contractual.

Where is TAP302762 substation located?

TAP302762 is in California at 40.5786, -122.3529. The datacenter candidate sites closest to it are in Tehama County, Shasta County, Trinity County.

Are there datacenter candidate sites near TAP302762 substation?

GridCensus lists at least 8 scored candidate sites within roughly 25 miles of TAP302762. The highest-scoring is OLINDA at 55/100. Across California, the average DC Readiness score is 45.4.

More in California

About this data

Source: HIFLD Electric Substations and Transmission Lines (U.S. Department of Homeland Security), as published June 29, 2026. See the methodology for how records are matched, cleaned and scored.

Cite as: GridCensus, “TAP302762 substation, California”, https://gridcensus.com/substations/california/tap302762-548d7ea0 (data as of June 29, 2026).

Dataset updated . Screening estimates derived from public data sources.

Substation attributes are derived from public HIFLD / EIA infrastructure data and may lag real-world upgrades or retirements. Voltage and connected-line counts are screening figures — confirm available capacity and interconnection terms directly with the operating utility and ISO.

Go deeper than the public screen

Every site and score for TAP302762 substation, California is free to browse. Pro adds Watchtower on 25 sites, alerts when new candidate sites, datacenters or interconnection-queue requests appear in your markets, score and capacity history, and CSV export. Enterprise adds team seats, weekly data files for all 147,272 sites, the REST API and an MCP server for AI tools.