CHESTER STATIC VAR COMPENSATOR

Substation

Maine

Max voltage
345
kV

CHESTER STATIC VAR COMPENSATOR is an electric transmission substation in Maine. It is classified as high-voltage (345 kv) and connects 1 transmission line. Substation proximity is one of the strongest speed-to-power signals for siting a datacenter — interconnection distance to an energized, high-voltage bus is often the binding constraint on time-to-energization.

Voltage & classification

Max voltage345 kV
Min voltage345 kV
Voltage classHigh-voltage (345 kV)
Connected lines1

Ownership & operation

Operator not catalogued for this substation.

StateMaine
Coordinates45.3972, -68.5291

Connected transmission lines

Lines terminating at or passing through this substation, by HIFLD line ID, highest voltage first.

Line IDVoltageOwnerStatusLength
#45233345 kVIN SERVICE0.2 mi

Browse the full transmission-line map →

Nearby datacenter candidate sites

Scored candidate sites within roughly 25 miles of CHESTER STATIC VAR COMPENSATOR, ranked by DC Readiness. Sites this close to an energized substation carry a strong speed-to-power advantage.

Candidate sites near CHESTER STATIC VAR COMPENSATOR substation
SiteTypeStateCountyVoltageCapacityQueue waitScore
CHESTERSubstation-AdjacentMEPenobscot County345 kV600 MW3.5 yrs67.7
UNKNOWN136689Substation-AdjacentMEPenobscot County115 kV100 MW3.5 yrs60.9
Greenfield (CHESTER - None)GreenfieldMEPenobscot County345 kV600 MW3.5 yrs60.1
Greenfield (CHESTER - None)GreenfieldMEPenobscot County345 kV600 MW3.5 yrs59.7
Greenfield (ORRINGTON - CHESTER)GreenfieldMEPenobscot County345 kV600 MW3.5 yrs58.5
Greenfield (CHESTER - None)GreenfieldMEPenobscot County345 kV600 MW3.5 yrs58.4
Greenfield (ORRINGTON - CHESTER)GreenfieldMEPenobscot County345 kV600 MW3.5 yrs57.9
INDECK WEST ENFIELD ENERGY CENTERSubstation-AdjacentMEPenobscot County115 kV100 MW3.5 yrs57.7

Dataset updated . Screening estimates derived from public data sources.

Substation attributes are derived from public HIFLD / EIA infrastructure data and may lag real-world upgrades or retirements. Voltage and connected-line counts are screening figures — confirm available capacity and interconnection terms directly with the operating utility and ISO.